WA Heavy-duty Slurry Pump
Kodi heavy duty slurry pump ndi chiyani?
WA mndandanda heavy duty slurry mpope ndi cantilevered, yopingasa, mphira zachilengedwe kapena zitsulo zolimba alimbane mapampu a centrifugal slurry. Amapangidwa kuti azigwira abrasive, slurries osalimba kwambiri muzitsulo, migodi, malasha, mphamvu, zomangira ndi dipatimenti ina yamakampani.
Zolemba za pampu yolemetsa
Kukula: 1 "mpaka 22"
Mphamvu: 3.6-5400 m3 / h
Kutalika: 6-125 m
Kupereka zolimba: 0-130mm
Kukhazikika: 0% -70%
Zida: Hyper chrome aloyi, Rubber, Polyurethane, Ceramic, Stainless steel etc.
AIER® WA Heavy Duty Slurry Pump
Mawonekedwe a slurry pump
1. The chimango mbale kwa WA mapampu mndandanda ali interchangeable zitsulo zolimba kapena kuthamanga kuumbidwa elastomer liners. Ma impellers amapangidwa ndi zitsulo zolimba kapena zomangira zolimba za elastomer.
2. Zisindikizo za shaft za mndandanda wa WA zikhoza kunyamula chisindikizo, chisindikizo cha centrifugal kapena chisindikizo cha makina.
3. Nthambi yotulutsa imatha kuyikidwa pazigawo za madigiri a 45 mwa pempho ndikuyang'ana malo aliwonse asanu ndi atatu kuti agwirizane ndi kukhazikitsa ndi kugwiritsa ntchito. Pali njira zambiri zoyendetsera galimoto, monga V-lamba, kugwirizana kosinthika, gearbox, hydraulic coupler variable frequency, silicon controlled speed, etc. Pakati pawo, flexible shaft coupling drive ndi V-lamba yotsika mtengo ndi kuyika kosavuta.
4. In harsh conditions with sand, sludge, rocks and mud, ordinary slurry pumps tend to clog, wear and fail frequently.. But our heavy-duty slurry pumps are highly resistant to wear and corrosion, which means that the moyo wautumiki wa mapampu athu amatope ndi bwino kuposa mapampu opanga ena.
Mapampu olemetsa omwe amagwiritsidwa ntchito
Chifukwa mapampu athu a WA heavy duty slurry ndi osamva kuvala komanso dzimbiri, mapampu olemetsa amagwiritsidwa ntchito pazinthu zosiyanasiyana.
1. Kutulutsa mphero ya SAG, kutulutsa mphero, Rod mil kutulutsa.
2. Ni acid slurry, coarse mchenga, coarse tailings, phosphate masanjidwewo, mchere tcheru.
3. Heavy media, sugar beet, dredging, pansi / ntchentche phulusa, laimu akupera, mafuta mchenga, mchere mchenga, michira zabwino, slag granulation, asidi phosphoric, malasha, flotation, ndondomeko mankhwala, zamkati ndi pepala, FGD, chimphepo chakudya, etc. .
Mapampu notation
200WA-ST: | 100WAJ-D: |
200: M'mimba mwake: mm | 100: M'mimba mwake: mm |
WA: Mtundu wa pampu: aloyi ya chrome yokhala ndi mzere | WAJ: Mtundu wa mpope: mphira ali ndi mzere |
ST: Mtundu wa mbale ya chimango | D: Mtundu wa mbale ya chimango |
Kuti mudziwe momwe mungathetsere mavuto anu opopera, Lumikizanani nafe today! We are the slurry pump manufacturer that can help you solve your problems.
Zomangamanga Design
|
Casing Magawo ogawanika a chitsulo chachitsulo kapena ductile ali ndi zomangira zomangira ndipo amapereka mphamvu zothamanga kwambiri.
Zitsulo zolimba zosinthika ndi zomangira za elastomer |
Impeller Choyikapo chikhoza kukhala chopangidwa ndi elastomer kapena chitsulo cholimba. Zovala zomata zam'mbali zakuya zimachepetsa kuthamanga kwa chisindikizo ndikuchepetsa kubwereza. Ulusi woponyeramo ndi woyenerera bwino pama slurries. |
Mating faces in hard metal liners are tapered to allow positive alignment during assembly and allow components to be easily removed for replacement.
Pampu Part Material
Dzina la Gawo | Zakuthupi | Kufotokozera | Mtengo wa HRC | Kugwiritsa ntchito | OEM kodi |
Liners & Impeller | Chitsulo | AB27: 23% -30% chrome chitsulo choyera | ≥56 | Amagwiritsidwa ntchito povala kwambiri ndi pH pakati pa 5 ndi 12 | A05 |
AB15: 14% -18% chrome chitsulo choyera | ≥59 | Amagwiritsidwa ntchito ngati zovala zapamwamba | A07 | ||
AB29: 27% -29% chrome chitsulo choyera | 43 | Amagwiritsidwa ntchito pochepetsa pH chikhalidwe makamaka FGD. Itha kugwiritsidwanso ntchito ngati wowawasa kwambiri komanso kuyika kwa desulfuration ndi pH zosachepera 4 | A49 | ||
AB33: 33% -37% chrome chitsulo choyera | Itha kunyamula slurry wokhala ndi okosijeni wokhala ndi pH osachepera 1 monga phospor-plaster, nitric acid, vitriol, phosphate etc. | A33 | |||
Mpira | R08 | ||||
R26 | |||||
R33 | |||||
R55 | |||||
Mphete ya Expeller & Expeller | Chitsulo | B27: 23% -30% chrome chitsulo choyera | ≥56 | Amagwiritsidwa ntchito povala kwambiri ndi pH pakati pa 5 ndi 12 | A05 |
Iron imvi | G01 | ||||
Stuffing Bokosi | Chitsulo | AB27: 23% -30% chrome chitsulo choyera | ≥56 | Amagwiritsidwa ntchito povala kwambiri ndi pH pakati pa 5 ndi 12 | A05 |
Iron imvi | G01 | ||||
Chophimba / mbale yophimba, nyumba yonyamula & maziko | Chitsulo | Iron imvi | G01 | ||
Chitsulo chachitsulo | D21 | ||||
Shaft | Chitsulo | Chitsulo cha carbon | E05 | ||
Manja a shaft, mphete ya nyali / chotchinga, mphete yapakhosi, boti ya gland | Chitsulo chosapanga dzimbiri | 4Kr13 | C21 | ||
Chithunzi cha 304SS | C22 | ||||
Chithunzi cha 316SS | C23 | ||||
Mphete zolumikizana & zisindikizo | Mpira | Komatu | S21 | ||
Mtengo wa EPDM | S01 | ||||
Nitrile | S10 | ||||
Hypalon | S31 | ||||
Neoprene | S44/S42 | ||||
Viton | S50 |
Kutumiza Module Design
Chitsulo chachikulu chopopera, cylindrical Kupanga katundu wolemetsa, kunyamula ma metric pogwiritsa ntchito mafuta opaka mafuta kapena kuthira mafuta; anatsegula siriyo, mbali yomanga ya voliyumu yaing'ono ndi kudalirika mkulu. |
![]() |
![]() |
Shaft Bearing Assembly Mtsinje waukulu wokhala ndi chopindika chachifupi umachepetsa kutembenuka ndi kugwedezeka. Zolemera zodzigudubuza zimayikidwa mu cartridge yochotsamo. Pampu Base Mangani mpope m'munsi ndi chiwerengero chochepa cha mabawuti ndikusintha chowongolera pamalo abwino pansi pa nyumba yonyamula. Chophimba chotchinga madzi chimalepheretsa madzi otayira kuti asawuluke. Chivundikiro chachitetezo chimateteza madzi kuti asatayike kuchokera pachimake chonyamula.
|
Shaft Seal Module Design
![]() |
1. Bokosi Lolongedza 2. Patsogolo Lantern mphete 3. Kulongedza katundu 4. Kunyamula Gland 5. Sleeve ya Shaft |
1. Kutulutsa Gland 2. Wothamangitsa 3. Kulongedza katundu 4. Kuyika Gasket 5. Mphete ya Nyali 6. Kunyamula Gland 7. Mafuta Cup |
![]() |
![]() |
GRJ Mechanical Chisindikizo Mtundu wa GRG umagwiritsidwa ntchito pamadzi omwe saloledwa kuchepetsedwa. HRJ Mechanical Seal Mtundu wa HRJ umagwiritsidwa ntchito ngati madzi ololedwa kuchepetsedwa. Ceramic yolimba kwambiri komanso ally imatengedwa kuti ikhale ndi zigawo zotsutsana. Ili ndi kukana kwakukulu kwa abrasive & kugwedeza umboni wotsimikizira kuti kusindikiza kumatha kukhutitsidwa ndi kasitomala mumikhalidwe yosiyanasiyana.
|
Performance Curve
Kuyika Miyeso
Slurry Pump Impeller Selection
Slurry pump impeller is one of the most important parts of centrifugal slurry pumps. Depending on the application, slurry pump impeller selection is crucial to slurry pump performance. Slurry applications can be especially hard on the impeller of slurry pumps because of their abrasive nature. In order slurry pumps operates efficiently and stand up to the test of time, impeller has to be selected properly for slurry pumps.
1. Slurry Pump Impeller Type
Pali mitundu itatu yosiyanasiyana ya slurry pump impellers; lotseguka, lotsekedwa, ndi lotseguka. Iliyonse ili ndi mphamvu ndi zofooka zake, malingana ndi ntchito. Zina ndi zabwino kwambiri zogwirira ntchito zolimba, zina ndi zabwinoko pakuchita bwino kwambiri.
Any type of impeller can be used in slurry applications, but closed slurry pump impellers are more common because they are high efficient and abrasion Resistance,. Open slurry pump impellers are usually used well for high concentration solids as they are less likely to clog. For example, the small fibers in paper stock which, in high densities, may have a tendency to clog the impeller. Pumping slurry can be difficult.
2. Slurry Pump Impeller Kukula
The size of slurry pump impeller must be considered to ensure it holds up against abrasive wear. Slurry pump impellers are generally larger in size when compared to slurry pumps for less abrasive liquids. The more “meat” the impeller has, the better it will hold up to the task of pumping harsh slurry mixtures. Just think of slurry pump impeller as a football team’s offensive line. These players are usually large and slow. Throughout the whole game they are beaten up, over and over again, but expected to withstand the abuse. You wouldn’t want small players in this position, just like you wouldn’t want a small impeller on your slurry pumps.
3. Slurry Pump Speed
Process speed doesn’t have anything to do with choosing slurry pump impeller, but it does have an effect on the life of slurry pump impeller. It is important to find the sweet spot that allows the slurry pump to run as slow as possible, but fast enough to keep solids from settling and clogging. If pumping too fast, the slurry can quickly erode the impeller due to its abrasive nature. This is why it is important to select a larger impeller if possible.
When dealing with slurry, you generally want to go bigger and slower. The thicker the impeller, the better it will hold up. The slower the pump, the less erosion will inflict on the impeller. However, the impeller isn’t the only thing to worry in slurry pump when dealing with slurry. Tough, durable materials of construction are necessary most of the time. Metal slurry pump liners and wear plates are common in slurry applications.
Kuyika kwa Slurry Pump
Kuyika Pampu ya Horizontal Slurry
The mounting and installation of horizontal slurry pumps are generally subject to a number of considerations, including floor space, overhead space for lifting and the likelihood of flooding from spills. Pumps in critical services are often paired in duty/standby mode so that maintenance can be carried out on one pump while the other is running.
Large slurry pumps with high-energy motors - and perhaps with speed reduction gearboxes - would generally be mounted with the shaft axes in the same horizontal plane for ease of maintenance access.
A slurry pump with a belt drive may have the motor mounted beside it if there is sufficient floor space. However, if floor space is limited or there is a risk of flooding, the motor can be mounted above it either directly overhead (also known as “C drive”) or to its rear (reverse overhead mounting or “Z drive”).
Vertical Slurry Pump Installation
Vertical cantilever shaft sump pumps should be selected so that the suction inlet is close to the sump floor. If shaft length is limited by the required running speed and power to be transmitted, a suction pipe (generally two meters long) may be fitted to the suction branch to ensure the sump can be emptied.