china electric slurry pump suppliers

Latest articles



Links


  • Post time: 24-02-23
  • Hexagonal cage has a wide range of applications, with the progress of science and technology, has been extended to the major hydraulic, civil engineering. Geotechnical engineering and other projects. In the hydraulic hexagonal cage in the river construction to close the utility, it is considered appropriate to use hexagonal cage to fill stone, fixed river, can be used to avoid river erosion brought water and soil loss. In civil engineering projects, hexagonal cage is considered appropriate and the use of similar particle size volume filling, the connection between the cage is formed into a wall, which is the stone cage mesh retaining wall.


  • Post time: 23-12-22
  • Hard black galvanized iron wire is made of low carbon steel wire by wire drawing machine. Hard black galvanized iron wire is the first feature of high hardness, bright appearance. It is mainly used for welding clothes hanger, umbrella, metal mesh, basket, basket and other metal products. Soft black galvanized iron wire is made of low carbon steel wire after annealing and softening, and then cold drawing. Soft black galvanized iron wire is the first feature of good flexibility, slightly higher hardness, bright appearance. Mainly used for metal mesh weaving technology, welding net, process products of welding.

  • The characteristics of these cages are small, light, easy to carry and easy to clean. For small animal cage, the wire diameter of the general iron wire is not very large, the thickness of the plastic is relatively thin, so the use of the time can not be “violence”, otherwise the cage in the “destruction” will occur under the welding or plastic crack.

  • And for the external insulation system is used in the brick veneer, as for the role of first should also be anti fall off followed by anti cracking, so should choose the grid 10×10×0.6, these are some experience choice, grid conversion from the national regulations of steel mesh specifications, using steel level conversion. The index of wire mesh size, wire warp, square meter steel content, galvanized amount, etc., mainly consider the corrosion resistance of wire mesh and the safety of the system! Galvanized wire mesh is more critical than wire diameter, galvanized amount is very important, must be hot plating, welding after plating is better than plating after welding, as for wire diameter, comprehensive consideration of site construction and to meet the needs of safety, 0.6 ~ 0.7 is better.

  • Strictly control the pH value of large roll galvanized wire bath, research shows that the size of the bath pH value directly affects the quality of steel wire coating, improper control of pH value will cause loose coating. When the pH value is greater than 3, the steel wire coating has burr caused by fine dendrites, and the surface is not smooth. The current density is strictly controlled. From the microscopic morphology, the higher the current density, the larger the zinc layer grain deposition, the less dense the corresponding zinc layer.

  • barbed

  • barbed

  • Pure zinc is more stable in dry air. In moist air or water containing carbon dioxide and oxygen, the surface will generate a layer of basic zinc carbonate based thin film layer, which can delay the corrosion rate of zinc layer. Comparison of corrosion resistance of zinc coating in aqueous solution of acid, alkali and sodium chloride; It is also resistant to corrosion in atmospheres containing carbon dioxide and hydrogen sulfide and in oceanic atmospheres; In high temperature and high humidity air and contain organic acid atmosphere is small, galvanized layer is also easy to be corroded.

  • Dip is one of the anticorrosion methods of galvanized diamond net. For hook mesh immersion is one of the methods of anti-corrosion, now the domestic more mature method is: powder immersion method, it originated from the fluidized bed method, the so-called fluidized bed is used in the Winkler gas furnace on the oil contact decomposition, and then developed the solid-gas two-phase contact process, gradually used in metal coating. So sometimes it is still called “fluidized bed coating method”, the actual process is to add the powder coating to the bottom of the porous, breathable container, the blower from the bottom into the treated compressed air, so that the powder coating turned to the “fluidization state”. It becomes a fine, evenly distributed powder.

  • Deoxygenation of boiling steel is incomplete, oxygen content is high, phosphorus and other impurities distribution is uneven, local overspending, aging sensitivity and cold brittle sensitivity are high, hot cracking tendency is added. If unqualified electrode is used, if the content of carbon and sulfur in the weld metal is too high, cracks will occur. For example, when factories use acidic electrodes to weld Q235-A steel, the high carbon fernoganese in the electrode coating will lead to thermal cracks in the weld.
  • After annealing, iron wire will become softer and more flexible. Iron is a more active metal, and more active than hydrogen, so it is a good reducing agent. At room temperature, iron is not easy to react with oxygen, sulfur, chlorine and other non-metallic elements in dry air, its production cost is low, the use and scale is relatively wide, better protective function, so it is an important material for steel parts used in strict working environment.

  • When the ground is undulating, the installation method of barbed rope also needs to be changed accordingly, because the installation of the original installation method will not play a protective effect.

  • Hot dip galvanizing is in the hot melt zinc liquid dip plating, production speed, thick but uneven coating, the market allows the thickness of 45 microns, up to 300 microns above. It is dark in color, consumes more zinc metal, forms infiltration layer with base metal, and has good corrosion resistance. Hot dip galvanizing can be maintained for decades in outdoor environment. The protection of zinc coating on iron matrix has two principles: on the one hand, although zinc is more active and easy to oxidize than iron, but its oxide film is not as loose and compact as iron oxide. The dense oxide layer formed on the surface inhibits the further oxidation of zinc in the interior.
  • There are a variety of arc, non-divergence Angle and non-divergence height ladder types installed to provide ideal treatment plans. It can be used together with the appearance and the common design of the trackless active shift door, forming a harmonious and intact whole.