heavy duty vertical froth pump manufacturers

Latest articles



Links

  • The surface of alluvium before hot dip galvanizing of orchard special electric galvanized shaft wire can partially remove the surface film layer, surface impurity and other shortcomings according to the basic technology to find and solve; Excessive foam is caused by soap and soapable surface active substances such as human fat into the tank. A moderate rate of foam production would be fine. There are many fine homogeneous particles in the tank, can stabilize the foam layer, with activated carbon mat to remove surface active substances. Or make the bubble unstable according to overworry, these are all reasonable countermeasures; Other strategies should also be used to reduce the amount of surface-active substances introduced. The introduction of organic matter can make the electroplating process speed drop sharply. Although the secret recipe of organic chemistry is beneficial to the high accumulation rate, the thickness of the coating can not meet the requirements after the organic matter is brought in, so the activated carbon can be used to solve the tank.

  • Galvanized


  • Post time: 19-04-23
  • 1, galvanized wire mesh molding sheet must be packed with flat hard data, to avoid eternal deformation due to poor packaging. It IS VERY IMPORTANT THAT EACH PACKAGE AND ROLL OF RAW SHEET MATERIAL BE MARKED WITH PRODUCT NAME, STANDARD, QUANTITY, TRADEMARK, batch number, MANUFACTURER, DATE of production, STACKING SYMBOL, INSPECTOR CODE AND INSPECTION CERTIFICATE.


  • Post time: 26-10-22
  • Bridge protection system generally do not need to be specially installed special drainage system, the use of hexagonal mesh made of gabion mesh box, the inside of the filler are selected stones, these stones are not easy to wear, and between the stones and stones will retain some gaps, so it is very good to meet the drainage requirements.

  • The size of the galvanized layer of galvanized iron wire is related to the anti-corrosion ability and application effect of galvanized wire. The thickness of the galvanized layer of the general standard galvanized wire products should be tested after the product is formed. There are three specific test methods. Weighing method and cross section microscopy method are destructive experimental methods, and magnetic method is a relatively rigorous non-destructive method, but the measurement steps and requirements are relatively high, so they are rarely used in specific applications. The first two methods are intuitive and common methods.

  • pet

  • Preparation process: single twist plait, double twist plait.
  • The principle of wire mesh mesh size, wire, square meters of steel content, galvanized amount, etc., to consider the corrosion resistance of wire mesh and the safety of the system! Wire mesh galvanized than wire diameter more fierce, galvanized quantity is very important, must be hot plating, welding after plating than plating after welding, as for wire diameter, induction and consideration of site construction and meet the needs of Ann.

  • galvanized

  • The installation of guardrail should also follow certain steps, first of all, after the guardrail is transported, according to the length of the guardrail, determine the distance between the column, if the installation of the guardrail field is soft ground, then you can first dig out a 40*40*50cm embedded machine base. If it is a concrete floor, as long as the expansion bolt directly fixed.

  • 5. Dry it with a towel.
  • Blade thorn rope because the volume is relatively large so thorn rope factory is used to packaging treatment.

  • Cold galvanizing (galvanizing) is in the plating tank after the current unidirectional, so that the zinc gradually plated on the metal surface, slow production speed, uniform coating, thin thickness, usually as long as 3-15g, bright appearance, poor corrosion resistance, usually a few months will rust. Compared with hot dip galvanizing, the production cost of electric galvanizing is lower.

  • Galvanized hook net price is low: galvanized anti-rust cost is lower than the cost of other paint coating; Galvanized hook mesh durable: galvanized layer and steel is metallurgical combination, become a part of the steel surface, so the durability of the coating is more reliable; Galvanized hook net impact resistance: galvanized layer forms a special metallurgical structure, this structure can withstand mechanical damage in transport and use; Galvanized hook mesh quality is high: every part of the plated parts can be plated with zinc, even in the depression, sharp corners and hidden places can be fully protected.

  • Wire-wall welding net is widely used in industrial production, agriculture, engineering construction, transportation, mining and other processing and manufacturing industries. Such as machinery and equipment protective cover, animal guardrail, pot flower guardrail, window fence, safety exit guardrail, poultry cage, egg basket and home office food industry basket, paper basket and design decoration. It is suitable for general engineering building wall, pouring concrete, multi-storey building, etc., which plays an important structural role in the thermal insulation system. In the construction of the building, the thermal insulation board of hot-dip galvanized electric welding grid is placed on the inside of the outer mold of the wall to be concreted. The external thermal insulation board and the wall are one kind of live, and the thermal insulation board and the wall are integrated into one body after the removal of the mold. The coating on the surface of the weld core is called the coating. The coating of electrode plays a very important role in the welding process. If the photoelectrode without drug skin is used for welding, in the welding process, oxygen and nitrogen in the air will invade a large number of molten metal, metal iron and beneficial elements such as carbon, silicon, manganese oxidation and nitriding to form various oxides and nitrides, and residual in the weld, resulting in slag inclusion or cracks in the weld. The gas in the weld pool may produce a large number of pores in the weld. These factors can greatly reduce the mechanical properties of the weld and make it brittle.

  • For the specification of galvanized wire, the galvanized wire produced by our factory can range from No.8 to No.22, which refers to the BWG standard, that is, from about 4mm to 0.7mm, which can basically cover the type required by the customer. As for the raw material of galvanized wire, normally, we use Q195 mild steel, and some factories will also use SAE1006 or SAE1008. The following is the zinc coating, for galvanized wire, this is very important, the general zinc coating is about 50g/m2 to 80g/m2, some customers need high zinc galvanized wire, zinc coating can reach 200g/m2 to 360g/m2. The tensile strength of galvanized wire is usually 350n/m2 to 800n/m2. Then there is the packaging specification of galvanized wire. The specifications of small rolls of galvanized wire are 50kg/ roll, 100kg/ roll and 200kg/ roll. Of course, there are large rolls of galvanized wire, the weight can reach 300kg/ roll or 800kg/ roll.